+ | - Do I have to do this to get vias? This seems very time consuming. | ||
+ | - What's the deal with training? | ||
- What are the different baths? | - What are the different baths? | ||
- Why don't we use bath 4? | - Why don't we use bath 4? | ||
Line 25: | Line 27: | ||
---- | ---- | ||
=== Q & A === | === Q & A === | ||
+ | **Do I have to do this to get vias? This seems very time consuming.** | ||
+ | It is indeed time consuming, but plating is typically avoidable by making vias with a diameter of 40 mil (1 mm). A standard 0.1” header pin can then be pushed through and soldered on both the top and bottom. Boom. | ||
+ | |||
+ | **What' | ||
+ | We used to lump the electroplater training into the plotter and laser trainings, but it was a long session with the plater normally tacked on at the end as an afterthought, | ||
+ | |||
+ | So, here's the situation: | ||
+ | |||
+ | If you were trained on the plater in a previous life and would like access, great - shoot us an email. We'll see if we can work something out, though likely we'll just ask you to watch the video anyway, since it's only 30 minutes. | ||
+ | |||
+ | If you have never been trained on the plater but would like to be, also great - see our [[pcb-training|Training]] page for all the details. It's essentially the same process and the plotter/ | ||
+ | |||
**What are the different baths?**\\ | **What are the different baths?**\\ | ||
Baths 1 and 2 are different cleaners, called (appropriately) Cleaner 110 and Cleaner 210, respectively. Both are based on sodium metaborate. Bath 3 is Activator 310, a carbon-laced liquid that provides a conductive pathway for the copper plating onto non-conductive surfaces, such as FR4. Bath 4 is a ViaCleaner that isn't used at the Hive (as of Spring 2021). Bath 5 is called Copper Plater 400; it's sulfuric acid (97% strength) and copper sulfate. Don't stick your hand in it. Please. See the [[https:// | Baths 1 and 2 are different cleaners, called (appropriately) Cleaner 110 and Cleaner 210, respectively. Both are based on sodium metaborate. Bath 3 is Activator 310, a carbon-laced liquid that provides a conductive pathway for the copper plating onto non-conductive surfaces, such as FR4. Bath 4 is a ViaCleaner that isn't used at the Hive (as of Spring 2021). Bath 5 is called Copper Plater 400; it's sulfuric acid (97% strength) and copper sulfate. Don't stick your hand in it. Please. See the [[https:// |